HD8/LD8/PRO8 Fog Fluid Safety Data
As required by Law, Coshh etc

Mid and West Wales Fire and Rescue Service 

1.  INTRODUCTION

The note is prepared for those planning to used smoke and dry ice machines in theatres, discos, etc.

2.  USE OF SMOKE OR FOG MACHINES

2.1.  The machines should be sited so that it does not cause a hazard to surrounding risks, such as curtains or drapes.

2.2.  The machine should be sited so that it does not obstruct exit routes.

2.3.  The machine should be sited and the volume of smoke controlled such that it does not seriously affect means of escape or obstruct exit signs. It is advisable to limit the amount of smoke in public areas to the minimum necessary for the desired effect.

2.4.  The smoke produced is to be non-toxic and non-flammable.

2.5.  Smoke generators must be in a fixed position, adequately protected against interference by members of the public, and manned by, or be readily accessible to, a competent operator at all times the machine is in use. The smoke outlets must also be within sight of the operator at all times.

2.6.  Smoke outlets must not be sited where smoke can be discharged, drift on or into exits, exit ways, staircases, means of escape routes, etc.

2.7.  Actual operation of the machine should take account of public safety and should be limited to the minimum amount of time required to achieve the necessary level of density.

2.8.  Ventilation in the area must be in an upward direction and must be in operation throughout the whole period.

2.9.  Where necessary, fans should be used to direct the smoke into the desired area in order to prevent clouding at the point of discharge and possible overspill into other parts of the premises.

2.10.  Before the use of a smoke or vapour effect is approved, consideration should be given to any automatic fire detection or fire sensor installed in the premises.

Ref: Mid and West Wales Fire and Rescue Service 

 